Many buyers bought parallel inverter and want to install it in 3 phase, but don’t understand how to connect and setting. I will teach you below, please read it one by one carefully:

3phase 380V parallel connect for 5.5kw
Cables install picture for three phase 380V input and output

Firstly, please you connect the cable as below (PV+Ac+battery)

Yellow wire is L1, black wire is N
Green wire is L2, Black wire is N
Red line is L3, Black line is N
page NO.27 setting to PAF

Press Enter 10S, and find the Page No.27, and setting to “PAF”, and press ENTER to confirming setting.

the mini jumper must be insert to the board before parallel connection

The mini jumper must be insert to the board before parallel connection (if you connect 3 pcs inverter, you just need put 1 jumper in one of them)

parallel cable connection

Parallel cable connect between them

Stating all the inverter fast

shenzhenbuyit

Starting all the inverter fast

Output voltage between L1 and N is 230V(±5V)

Output voltage between L1 and N is 230V(±5V)

Output voltage between L1 and L2 is 398V(±5V)

Output voltage between L1 and L2 is 398V(±5V)

if you still have questions about this blog, you can call us or add what’s app: 008613808405352